AeroDR X90 A premium fully motorized digital x-ray system
At IDSM, our commitment to excellence goes beyond providing cutting-edge medical solutions. We understand the critical importance of reliable service and support in the field of X-ray diagnostics. With a team with extensive experience, education and international training, we are ready to meet the unique challenges in the field of diagnostic imaging.
- Ergonomic design
- Fully motorized
- Automatic tracking
- Automatic positioning
- Smart and easy to use system
- AeroDR unique wireless flat panel detectors
Ergonomics and automation
The AeroDR X90 contains a large tube display with patient information, image preview and easy adjustment of x-ray parameters. The smooth floating table, flexible table height and tilting wall mount make the AeroDR X90 an optimal ergonomic solution for the patient and operator.
Smart and easy to use
Automatic positioning, along with the floating table top and adjustable wall mount, makes patient positioning easy. This will create a comfortable environment for both the patient and the operator. Good viewing angle of the tube display and a user- friendly interface supports easy review of information and quick changes to support a smooth work flow AeroDR X90 in combination with AeroDR flat panel detectors makes it easy for the user to switch between different type of exams.
Intuitive workflow
The graphical User Interface of the AeroNAV acquisition software allows you to easily navigate your workflow by using user-friendly screen layouts and simplified automated workflow. In addition, the software includes various measurement and administration tools.
Best image quality
For radiography professionals who demand the highest level of confidence, the AeroDR HD has an astonishing pixel size of just 100 μm! It allows you to magnify microstructures to perform precise analyzes needed for limbs, pediatrics and other specialties where image detail and dose efficiency are vital to diagnosis.
Ergonomics and automation
The AeroDR X90 contains a large tube display with patient information, image preview and easy adjustment of x-ray parameters. The smooth floating table, flexible table height and tilting wall mount make the AeroDR X90 an optimal ergonomic solution for the patient and operator.
Smart and easy to use
Automatic positioning, along with the floating table top and adjustable wall mount, makes patient positioning easy. This will create a comfortable environment for both the patient and the operator. The tube display’s good viewing angle and user-friendly interface support easy information viewing and quick changes to support a smooth workflow AeroDR X90 in combination with AeroDR flat detector panels makes it easy for the user to switch between different types of studies.
Intuitive workflow
AeroNAV acquisition software’s graphical user interface allows you to easily navigate your workflow using user-friendly screen layouts and a simplified automated workflow. In addition, the software includes various measurement and administration tools.
Best image quality
For radiography professionals who demand the highest level of confidence, the AeroDR HD has an astonishing pixel size of just 100 μm! It allows you to zoom in on microstructures to perform precise analyzes needed for limbs, pediatrics and other specialties where image detail and dose efficiency are vital to diagnosis.
AeroDR X90 Specifications:
Generator:
- mAs - 0,4-1000 mAs;
- Tube Current – 10-1000 mA;
- Output – 65kW + Option to 80kW;
- Exposure time – 1 ms – 10 s;
- Exposure voltage – 40 to 150 kVp;
X-Ray Tube:
- Focal spot sizes – 0.6/1.2 mm;
- Max kVp rating – 150 kV;
- Nominal Anode input power – 40/100 kW;
- Small focus – 5.4 A (exposure) / <=2.5 A (stand by);
- Large focus - 5.4 A (exposure) / <=2.8 A (stand by);
- Anode heat storage – 300 kJ (400 kHU) + Option to 445 kJ (600 kHU);
Collimator:
- Lamp – LED;
- Rotation angle - ±90°;
- Shape of the radiation field – Square field multilayer;
- Beam limiting method – Manual mode or Automatic mode;
- Center marker – Center of the radiation field is indicated by a cross;
- Filtration – No filter, 1mmAl+0.1mmCu, 1mmAl+0.2mmCu, 2mmAI+0.3mmCu;
- Bucky light – Radiation field center is inducated by laser beam for positioning;
Overhead tube crane:
- Column (Z stroke) – 1750 mm;
- Top Head Pipe Faucet:
- Tube Head Display – 12.1 inch;
- Rotation tube arm (Alpha) - >±135°;
Table:
- Movement – 6-way;
- Vertical stroke – 380 mm;
- AI equivalent – 0.9 mm;
- Operating method – Motorized;
- Table top thickness – 21.5 mm;
- Table top dimension – 2424x850 mm;
- Movement range of the detector - >850 mm;
- Length of table top stroke, Y direction - ± 150 mm;
- Length of table top stroke, X direction - ± 600 mm;
- Lowest table top position to floor – 550 mm;
- Table top X-Ray transparent area – 2400x613 mm;
- Movement range of the imaging unit (bucky) – 770 mm;
- Patient Load (Dynamic load center) – 300 kg;
- Movement of the imaging unit (bucky) – Motorized and manual;
Wall Stand:
- Vertical stroke – 1580 +10/-10;
- Tilting angle – (-20° / -90°);
- Speed Z movement – 200 mm/s;
- Operating method – Motorized and manual;
- Balancing mechanism: Counterweight;
X-Ray Grids:
- Grid ratio – 10:1;
- Interspace material – Al;
- Grid density – 40, 52 lp/cm;
- Cover material – Al or Carbon;
- Focusing distance: - 40 lp/cm: 115cm, 150cm, 180cm; - 52 lp/cm: 110cm, 140cm, 180cm.